Core criteria in high-temperature measurement

Sensor life in foundries, annealing furnaces and high-temperature processes depends on temperature level, atmosphere, thermal shock, mechanical impact and protection tube material. Thermocouple type and protection design must be selected together.

Thermocouple type selection

Type K thermocouples are widely used in many industrial applications. Type S, R or B noble metal thermocouples may be preferred for higher temperatures and accuracy requirements.

Protection tube and installation

Ceramic protection tubes, metal sheaths or special alloys are selected according to process conditions. Proper immersion rate, preheating and mechanical protection are important where thermal shock risk exists.

Service life recommendations

  • Select suitable protection tube material
  • Reduce thermal shock
  • Protect cable and terminal head from hot zones
  • Apply periodic inspection and calibration

Quotation and engineering support

We can evaluate the correct product type, watt density, material selection and connection details for your application.